SpDistance Manual UT practice bench · prototype 0.6

checking
Gain 0.240.0 dB
--
--
--
--
--
--

Gain

Section at the probe

Plate, from above

Drag the probe. ←→↑↓ nudge it 1 mm, hold Shift for 0.2 mm. Tap the other side of the weld to move across.

0°

Bench

Probe
Scan from
Colour scheme
On a phone, add this page to your home screen to lose the browser bars: Share, then Add to Home Screen.
Peak the 100 mm radius first. Peak the Ø50 hole to read the probe angle off the scale.

Using the set. ◀ ▶ on the bottom row change the function group. ▲ steps up into the group, ▲ ▼ pick a function, ◀ ▶ change it in small steps and −− ++ in large ones. Hold a key to repeat. ▶ also triggers Record and DAC point. ● gives the full-width A-scan. You can tap a function or drag a gate directly. Keyboard: + − gain, 8 80%, F freeze, Q E swivel.

Report

#Y startY endLengthDepthFrom CLMax re DACType
Y is along the weld from the datum end. From CL is negative on side A.